5.8.3 Rebuild Settings
Press ENT for two seconds to enter the Main Menu. Press the up or down arrow keys to select
"View and Edit Config Parms," then press ENT.
Press the up or down arrow keys to select “Disk Array Parameters,” then press ENT.
Press the up or down arrow keys to select “Rebuild Priority Low,” then press ENT. “Low”
refers to the temporary default setting.
Press ENT again and the abbreviation mark “..” will change to a question mark “?”. Press the
up or down arrow keys to select priority “Low,” “Normal,” “Improved,” or “High”.
Press ENT to confirm and the question mark “?” will turn into “
..”.
i
NOTICE!
The rebuild priority determines how much of the system resources are used when rebuilding a
logical drive. The default setting of the rebuild priority is “Normal.” Rebuild will have less
impact on host I/O access, but will take a longer time to complete. Changing the priority to a
higher level will achieve a faster rebuild, but will significantly increase the host I/O response
time. The default setting “Normal” is recommended.