4.3 Logical Drive Status
Fig. 4.3 Logical Drive Status Screen
Logical Drive: The Logical Drive number.
RAID level: The RAID level applied for this logical drive.
Number of Drives: The number of physical drives included in this configuration.
Logical Drive status:
XxxxMB The capacity of this logical drive.
SB=x Standby drives available to this logical drive. Except the spares
dedicated to other logical configurations, all spare drive(s) will
be counted in this field, including Global and Local Spares.
xxxxMB INITING The logical drive is now initializing.
xxxxMB INVALID For firmware version before 3.31:
The logical drive has been created with “Optimization for
Sequential I/O”, but the current setting is “Optimization for
Random I/O.”
-OR-
The logical drive has been created with “Optimization for Ran-
dom I/O,” but the current setting is “Optimization for Sequen-
tial I/O.”
Firmware versions 3.31 and later have separate settings for
array optimization and array stripe size. This message will not
appear when the optimization mode is changed.
xxxxMB GD SB=x The logical drive is in good condition.
xxxxMB FL SB=x One member drive failed in this logical drive.
xxxxMB RB SB=x Logical Drive is rebuilding.
xxxxMB DRVMISS One of the drives is missing.
INCOMPLETE ARRAY Two or more drives failed in this logical drive.