Specifications

32 en | RAID Planning SCSI to SATA RAID Subsystem | Administrator’s Manual
F.01U.027.802 | V1 | 2006.11 Bosch Security Systems
Enclosure Monitoring:
(2) Periodic SAF-TE/
SES Device Check Time
30 seconds Disabled, 50ms~60 seconds
(2) Event Triggered
Operation
N/A Controller, fan, PSU, BBU, and elevated tempera-
ture
Auto-shutdown: 2 mins~1 hour
(1) Thresholds for Volt-
age and Temperature
Self-Monitoring
CPU temp:
0~90C
Board temp:
0~80C
3.3V: 2.9~3.6V
5V: 4.5~5.5V
12V:
10.8~13.2V
User-defined; do not change parameters unless nec-
essary
Others:
(3) Password N/A User-Defined; Password Validation Timeout: 1 sec-
ond to Always Check Configurable
(3) LCD Display Con-
troller Name
N/A User-defined
(1) Network Protocol
Support
All enabled
except SSH
No configuration options
(1) Cylinder/Head/ Sec-
tor Mapping
N/A Depends on host OS
Table 2.2 User-Defined Parameters