Specifications

SCSI to SATA RAID Subsystem | Administrator’s Manual Event Messages | en 231
Bosch Security Systems F.01U.027.802 | V1 | 2006.11
Message Controller NOTICE: NVRAM Factory Defaults Restored
What Happens? The factory defaults for configuration profile is restored.
What to Do? Press ESC to clear the message.
Message Controller BBU is Charging!
What Happens? Once a new BBU is installed or BBU charge drops below a preconfig-
ured level, the subsystem will start charging its batteries.
What to Do? Press ESC to clear the message. All batteries have a limited life expect-
ancy. If this message appears too frequently, the BBU may have gradu-
ally lost its ability to hold charge.
Message +12V Upper Voltage Back within Acceptable Limits (_._V)
What Happens? +12V voltage dropped back within preset thresholds.
What to Do? Check proper working condition and press ESC to clear the message.
Message NOTICE: Controller BBU Present!
What Happens? A BBU once missing or removed is now electrically connected to the
subsystem.
What to Do? Check proper working condition and press ESC to clear the message.
Message NOTICE: Controller BBU Back On-Line!
What Happens? A BBU once missing or removed is now restored to its normal working
condition.
What to Do? Check proper working condition and press ESC to clear the message.
Message NOTICE: Controller BBU Fully Charged!
What Happens? A BBU is fully charged.
What to Do? Check proper working condition and press ESC to clear the message.
Message Force Controller Write-Through on Trigger Cause
What Happens? Preset conditions, e.g., elevated temperature or component failure,
has forced the subsystem to adopt a more conservative operating
mode by disabling the Write-Back caching.
What to Do? Check proper working condition and correct system faults. Press ESC
to clear the message.