Specifications
224 en | Event Messages SCSI to SATA RAID Subsystem | Administrator’s Manual
F.01U.027.802 | V1 | 2006.11 Bosch Security Systems
Message Peripheral Set 0 Device ALERT: Cooling Fan 2 Note Present
What Happens? No cooling fan module is installed in the expected module slot.
What to Do? Check proper module installation or contact your RAID supplier for a
replacement module.
Message Peripheral Set 0 Device ALERT: Low Speed Detected(-1073870808
RPM)
What Happens? Low rotation speed detected on cooling fan. This is a fault detected
through an I2C serial bus.
What to Do? Check proper module installation or contact your RAID supplier for a
replacement module.
Message SES(C0 I0)Cooling Fan 0:Device Not Supported!
What Happens? Unrecognizable device type. This event may result from an incorrect
configuration with the SES remote device monitoring.
What to Do? Check proper module installation and contact your RAID system sup-
plier.
Message SAF-TE Device(0) ALERT: Elevated Temperature Alert
What Happens? Elevated temperature detected through SAF-TE monitoring device.
Improper installation site condition or cooling fan failure might have
caused the system temperature to rise.
What to Do? Check proper cooling and cooling fan working condition. Contact your
RAID system supplier.
Message
Peripheral Device ALERT: CPU Cold Temperature Detected(_._C))
What Happens? Temperature below the lower CPU threshold detected. Improper
installation site condition might have caused the situation.
What to Do? Correct your installation site condition. Contact your RAID system sup-
plier.
Message Peripheral Device ALERT: Elevated Temperature Alert
What Happens? High temperature threshold violated and detected through an I2C
serial bus. Improper installation site condition or cooling fan failure
might have caused the situation.
What to Do? Correct your installation site condition and cooling fan failure. Contact
your RAID system supplier if a replacement is necessary.
Message Peripheral Set 0 Device ALERT: Temperature Sensor 0 Failure Detected
What Happens? Temperature sensor failure reported through an I2C serial bus.
What to Do? Contact your RAID system supplier.