Specifications
220 en | Event Messages SCSI to SATA RAID Subsystem | Administrator’s Manual
F.01U.027.802 | V1 | 2006.11 Bosch Security Systems
Message SMART-Slot:_ Predictable Failure Detected-Starting Clone
What Happens? One or more hard Drive(s) reports SMART-detected defects. Starts
using a pre-defined spare drive to clone the member drive suspected
of inherent errors. This happens when SMART detection is enabled
with the “Copy & Replace” or “Perpetual Clone” reaction schemes.
What to Do? Press ESC to clear the message. After the cloning process, you may
consider replacing the defective drive with a good one and configure it
as a spare drive in case drive failure might happen in the future.
Message SMART-Slot:_ Predictable Failure Detected (TEST)
What Happens? This results from a manually executed test command. This ensures
your disk drive supports SMART detection and report functionality.
What to Do? Press ESC to clear the message.
Message CHL:_ ALERT: Redundant Loop for CHL:_ Failure Detected
What Happens? One of the dual loop members may have failed or been disconnected.
Make sure all channels are properly connected and topological configu-
rations properly set.
What to Do? Check cabling and system installation. Contact your supplier if no con-
nection errors could be found.
Message CHL:_ ALERT: Redundant Path for CHL:_ ID:_ Expected but Not Found
What Happens? One of the dual loop members may have failed or been disconnected.
This event is regenerated in the event when the one of dual loop con-
nections to an expansion enclosure can not be found after power-up.
Make sure all channels are properly connected and topological configu-
rations properly set.
What to Do? Check cabling and system installation. A manual “Issue LIP” command
may restore the connection. Contact your supplier if no connection
errors could be found.
Message CHL:_ ID:_ ALERT: Redundant Loop for CHL:_ ID:_ Failure Detected
What Happens? One of the dual loop members connecting device CHL:_ ID:_ may have
failed or been disconnected. Make sure all channels are properly con-
nected and topological configurations properly set.
What to Do? Check cabling and system installation. Contact your supplier if no con-
nection errors could be found.