Message CHL:_ RCC Channel ALERT: Invalid Status/Sense Data Received
What Happens? Invalid status/sense data received on the RCC channel CHL:_
What to Do? Rare occurrence of these errors can be managed by firmware. Contact
your RAID system supplier.
Message CHL:_ ID:_ Target ALERT: Invalid Status/Sense Data Received (10B)
What Happens? Invalid status/sense data received by a disk drive CHL:_ ID:_.
What to Do? Rare occurrence of these errors can be managed by firmware. Contact
your RAID system supplier.
Message CHL:_ Drive Channel ALERT: Invalid Status/Sense Data Received
What Happens? Invalid status/sense data received on the drive channel CHL:_
What to Do? Rare occurrence of these errors can be managed by firmware. Contact
your RAID system supplier.
Message CHL:_ ALERT: Redundant Loop Connection Error Detected on ID:_
What Happens? One of the dual loop members might have failed or been disconnected.
Make sure all cabling are properly connected and topological configu-
rations properly set.
What to Do? Check cabling and channel bus working conditions. If the problem
does not result from cabling problems, contact your RAID system sup-
plier.
Message CHL:_ Host Channel ALERT: Channel Failure
What Happens? Host channel CHL:_ link failure or disconnection occurred.
What to Do? Check proper cabling connection and host HBA, link connection
devices, etc. Contact your RAID system supplier.
Message SMART-Slot:_ Predictable Failure Detected-Clone Failed
What Happens? Hard Drive(s) report SMART-detected defects. A spare drive is com-
menced to clone or replace the member drive showing defects. The
cloning operation failed. The member drive suspected of errors might
have failed, or the clone process has been interrupted, e.g., yet
another member has failed or the spare drive used for cloning has
shown immanent faults.
What to Do? Carefully check drive status and replace the unstable/failed drive. Con-
tact your RAID system supplier.
Message SMART-Slot:_ Predictable Failure Detected
What Happens? Hard drive slot:_ reported SMART-detected errors, e.g., abnormal rota-
tion speed, seek time delay, etc.
What to Do? Carefully check drive status and replace the unstable/failed drive. Con-
tact your RAID system supplier.