Specifications

SCSI to SATA RAID Subsystem | Administrator’s Manual Firmware Functionality Specifications | en 195
Bosch Security Systems F.01U.027.802 | V1 | 2006.11
14.8 System Security
14.9 Environment Management
Password protection Supported. All settings require the correct password (if set)
to ensure system security.
User-configurable password
validation timeout
Supported. After certain time in absence of user interaction,
the password will be requested again. This helps to avoid
unauthorized operation when user is away.
SSL-enabled RAIDWatch
Agents
Agents communicate to the controller through limited set of
authorization options.
SAF-TE/S.E.S. support Supported. The SAF-TE/S.E.S. modules can be connected
to the drive channels. The RAID controller will detect
errors from SAF-TE/S.E.S. devices or notify drive failures
via SAF-TE/S.E.S.
Both SAF-TE/S.E.S. via drive and device-self-inter-
faced methods are supported.
Redundant SAF-TE/S.E.S. devices are supported
Multiple S.E.S. devices are supported
Dynamic on-lining of enclosure
services
Once an expansion unit (JBOD) with supported monitor-
ing interface is combined with a RAID system, its status
will be automatically polled.
SAF-TE/S.E.S. polling period User configurable (50ms, 100ms, 200ms, 500ms,
1~60sec)
Multiple SAF-TE/S.E.S. modules
on the same channel
Supported.
Multiple SAF-TE /S.E.S. modules
on different channels
Supported.
Mapping SAF-TE/S.E.S. device to
host channel for use with host-
based SAF-TE/S.E.S. monitoring
Supported.
Event Triggered Operation
When any of the following happens, the firmware dis-
ables write-back caching to minimize the chance of los-
ing data:
Battery, controller, cooling fan, or PSU failure
The upper temperature thresholds are exceeded
Low battery charge
The triggering factors are user-configurable
Dual-speed cooling fan control Yes
Dual-LED drive status indicators Supported. Both single-LED and dual-LED drive status
indicators are supported.
SAF-TE/ S.E.S. temperature value
display
Supported. Display the temperature value provided by
enclosure SAF-TE module (if available).
On-board controller voltage
monitors
Supported. Monitors the 3.3V, 5V, and 12V voltage status.
Event triggered thresholds user configurable.