Specifications

182 en | S.M.A.R.T. Configuration SCSI to SATA RAID Subsystem | Administrator’s Manual
F.01U.027.802 | V1 | 2006.11 Bosch Security Systems
Fig. 12.14 Predictable Failure Test
4. Choose “Predictable Failure Test.,” The controller will force the drive to simulate predict-
able drive errors.
Fig. 12.15 Choose Predictable Failure Testing
5. Press [ENTER], and after a while (the next time the controller performs “Periodic Drive
Check”), the controller will detect the errors simulated by the drive. An error message
displays like this: “SMART-CH:? ID:? Predictable Failure Detected (TEST).” If this error
message appears, it means your drive supports S.M.A.R.T. features.
6. If the error message does not appear, you may simply refer to related documentation or
contact your drive manufacturer for information about whether the drive model and drive
firmware version support S.M.A.R.T.
Using S.M.A.R.T. Functions
1. Enable “S.M.A.R.T.” on the RAID controller.
2. Make sure your drives do support S.M.A.R.T. so that your system will work properly.
3. The “Detect Only” Setting
In \View and Edit Configuration Parameters\Drive-side Parameters\Drive Predictable Fail-
ure Mode <SMART>, choose “Detect Only.”