Specifications
168 en | Array Expansion SCSI to SATA RAID Subsystem | Administrator’s Manual
F.01U.027.802 | V1 | 2006.11 Bosch Security Systems
11.5 Making Use of the Added Capacity: Expand Logical Drive
In the following example, the logical drive is originally composed of three member drives and
each member drive has the capacity of 1GB. “Copy and Replace” has been performed on the
logical drive and each of its member drives has been replaced by a new drive with the capacity
of 2GB. The next step is to perform “Expand Logical Drive” to utilize the additional capacity
brought by the new drives.
1. Select “View and Edit Logical Drives” from the Main Menu and select the logical drive
with its members copied and replaced.
2. Select “Expand Logical Drive” in the sub-menu and press [ENTER] to proceed. A confirm-
ing box will appear.
3. Proceed by pressing [ENTER] or entering any value no larger than the "maximum drive
expand capacity" and press [ENTER].
Fig. 11.16 Expand Logical Drive
Choose Yes to confirm and proceed.
Fig. 11.17 Choose Expand Logical Drive
Upon completion, you will be prompted by the notification message.
Fig. 11.18 Completed Expand Logical Drive
Press [ESC] to return to the previous menu screen.
The total capacity of logical drive has been expanded to 6GB.