Specifications

SCSI to SATA RAID Subsystem | Administrator’s Manual Array Expansion | en 165
Bosch Security Systems F.01U.027.802 | V1 | 2006.11
Fig. 11.8 Completion of Add Drive Function
The added capacity will be automatically included, meaning that you do not have to "expand
logical drive" later. Map the added capacity to another host ID/LUN to make use of it.
As diagrammed above, in "View and Edit Host LUN," the original capacity is 9999MB, its host
LUN mapping remains unchanged, and the added capacity appears as the second partition.
i
NOTICE!
Expansion by adding drives can not be canceled once started. If power failure occurs, the
expansion will be paused and the controller will NOT restart the expansion when power
comes back on. Resumption of the RAID expansion must be performed manually.
If a member drive of the logical drive fails during RAID expansion, the expansion will be
paused. The expansion will resume after the logical drive rebuild is completed.