Specifications
SCSI to SATA RAID Subsystem | Administrator’s Manual Array Expansion | en 163
Bosch Security Systems F.01U.027.802 | V1 | 2006.11
11.3 Mode 1 Expansion:
Adding Drives to a Logical Drive
Use drives with the same capacity as the original drive members. Once completed, the added
capacity will appear as another partition (new partition). Data is automatically re-striped
across the new and old members during the add-drive process. See the diagram below to get
a clear idea:
Fig. 11.2 Expansion by Adding Drive
RAID levels supported: RAID 0, 1, 3 and 5.
The new partition must be made available through a host ID/LUN.
Add Drive Procedure
First select from the Main Menu, “View and Edit Logical Drive,” and select a logical drive to
add a new drive to. The drive selected for adding should have a capacity no less than the orig-
inal member drives. If possible, use drives of the same capacity because all drives in the array
are treated as though they have the capacity of the smallest member in the array.
Fig. 11.3 Add Drive on Logical Drive
i
NOTICE!
The following figures in this chapter are showing examples using the management hyper ter-
minal screen.