Specifications
156 en | Data Integrity SCSI to SATA RAID Subsystem | Administrator’s Manual
F.01U.027.802 | V1 | 2006.11 Bosch Security Systems
• In the case of a periodic action, the action is executed at the specified “start time,” and
then re-enacted at the time interval indicated in the execution period so as to be exe-
cuted again later. The selectable interval ranges from one second to several weeks.
Media Scan Mode
Fig. 10.11 Set for Media Scan Mode
If the maintenance schedule includes more than one logical drive, the scan can be performed
simultaneously or separately on one disk at a time in a sequential order.
Media Scan Priority
Fig. 10.12 Set for Media Scan Priority
The scan priority determines how much of the system’s resources will be consumed to per-
form the scheduled task. Select “Low” for better array performance and longer time to com-
plete the media scan. Higher priority allows higher scan performance at the cost of reduced
array performance.
Select Logical Drives
Fig. 10.13 Set for Logical Drive
Press [ENTER] on “Select Logical Drives” to bring out a sub-menu. From there you may
include all configured arrays or press [ENTER] on “To Select Logical Drives” to select one or
more specific logical drive(s).
Logical drives can be tagged for inclusion by positioning the cursor bar on the logical drive
and then pressing [ENTER]. An asterisk (∗) mark will appear on the selected physical drive(s).
To deselect the drive, press [ENTER] again on the selected drive. The “∗” mark will disappear.
Use the same method to select more logical drives if required.
When selection is done, press [ESC] to continue.