9.2 SAF-TE and SES Enclosure Monitoring
9.2.1 Periodic SAF-TE and SES Device Check Time
Fig. 9.10 Set SAF-TE and SES Check Time
If there are remote components in your RAID enclosure being controlled via SAF-TE/S.E.S.
devices, use this function to select how often the controller will check the status of these
devices. Choose “Periodic SAF-TE and SES Device Check Time”; then press [ENTER]. Move
the cursor to the desired interval, then press [ENTER]. Choose Yes in the dialog box that fol-
lows to confirm the setting.
9.2.2 Enclosure Devices Status: View Peripheral Device Status
Select “View and edit Peripheral Devices” on the Main Menu and press [ENTER]. Choose
“View Peripheral Device Status,” then press [ENTER] again. The device list displays.
Below is a list of peripheral devices (enclosure modules) supported by enclosure monitoring.
Monitoring of device status depends on enclosure implementation and is accessed through
different interfaces, e.g., SAF-TE, S.E.S., or I
2
C serial bus.
1. Device type
2. Enclosure descriptor
3. Power supply
4. Cooling element
5. Temperature Sensors
6. Audible alarm
7. Enclosure services controller electronics
Below is a screen display showing enclosure
devices through an I
2
C serial bus: