Specifications
132 en | Host-side and Drive-side Parameters SCSI to SATA RAID Subsystem | Administrator’s Manual
F.01U.027.802 | V1 | 2006.11 Bosch Security Systems
Fig. 8.2 Maximum Concurrent Host LUN Connection
From the Main Menu, select “View and Edit Configuration Parameters,” “Host-side Parame-
ters,” then press [ENTER]. Choose “Max Number of Concurrent Host-LUN Connection,” then
press [ENTER]. A list of available selections will appear. Move cursor bar to an item, then
press [ENTER]. Choose Yes in the dialog box that follows to confirm your setting. The default
is “4.”
8.1.2 Number of Tags Reserved for Each Host-LUN Connection
Each nexus has 32 (the default setting) tags reserved. When the host computer sends 8 I/O
tags to the controller, and the controller is too busy to process them all, the host might start
to send less than 8 tags during every certain period of time since then. This setting ensures
that the controller will accept at least 32 tags per nexus. The controller will be able to accept
more than that as long as the controller internal resources allow - if the controller does not
have enough resources, at least 32 tags can be accepted per nexus.
Fig. 8.3 Number of Tags Reserved for Each Host-LUN Connection
Choose “Host-side Parameters,” then press [ENTER]. Choose “Number of Tags Reserved for
each Host-LUN Connection,” then press [ENTER]. A list of available selections will appear.
Move the cursor bar to an item, then press [ENTER]. Choose Yes in the dialog box that follows
to confirm the setting.