Specifications
SCSI to SATA RAID Subsystem | Administrator’s Manual Terminal Operation | en 127
Bosch Security Systems F.01U.027.802 | V1 | 2006.11
7.14.5 Password Validation Timeout
Fig. 7.70 Password Validation Timeout Page
Choose View and Edit Configuration Parameters, Controller Parameters, then press [ENTER].
Select Password Validation Timeout, and press [ENTER]. Choose to enable a validation timeout
from “1 minute” to “Always Check.” The Always Check timeout will disable any configuration
change made without entering the correct password.
7.14.6 Controller Unique Identifier
Fig. 7.71 View and Edit Configuration Parameters
Enter any hex number between “0” and “FFFFF” for the unique identifier. The value you enter
MUST be different for each controller.
Enter a unique ID for every RAID subsystem whether it is configured in a single-controller con-
figuration. The unique ID is necessary for the following:
1. MAC addresses for the controller’s Ethernet port that will be taken over by a surviving
controller in the event of single RAID controller failure.
2. The unique identifier setting can be accessed from "View and Edit Configuration Parame-
ters" -> "Controller Parameters" -> "Controller Unique ID."