Product specifications

Terminal Screen Messages
3-5
INVALID
The logical drive was created but has not been
fully initialized when another version of firmware
is being loaded. After the subsystem resets, the
array status should return to normal.
FATAL FAIL
Two member drives failed at the same time, the
array is inaccessible
DRV MISS
A member drive is missing; could result from
insecure installation
REBUILDING
The logical drive is being rebuilt
Status 2
Logical Drive Status – Column 2
I
Initializing drives
A
Adding drive(s)
E
Expanding logical drive
H
Add drive operation on hold
Status 3 Logical Drive Status – Column 3
R
Rebuilding the logical drive
P
Regenerating array parity
Column O Logical Drive Status – Stripe size
N/A
Default
2
4KB
6
64KB
3
8KB
7
128KB
4
16KB
8
256KB
5
32KB
9
512KB
A
1024KB
Column C Logical Drive Status – Write Policy setting
B
Write-back
T
Write-through
#LN
Total drive members in the logical drive
#SB
Standby drives available for the logical drive. This
includes all the spare drives (local spare, global spare)
available for the specific logical drive
#FL
Number of Failed member(s) in the logical drive
Name
Logical drive name (user configurable)