Product specifications
Infortrend
2-18
2.9.4 Rebuilding a Logical Drive (Manual Rebuild)
If you want the controller to auto-detect a replacement drive, make
sure you have the following options set to enabled:
1. Periodic Drive Check Time
2. Periodic Auto-Detect Failure Drive Swap Check Time
These two configuration options can be found under “View and Edit
Configuration Parameters” -> “ Drive-Side Parameters”.
A manual rebuild takes place after you
replace the failed drive with a new drive
that is known to be good.
Press ENT for two seconds to enter the
Main Menu. Press the up or down arrow
keys to select "View and Edit Logical
Drives..", then press ENT.
Use the up or down arrow keys to select
the logical drive that has a failed member,
then press ENT.
Use the up or down arrow keys to select
“Rebuild Logical Drive," then press ENT.
Press ENT for two seconds to start
rebuilding the logical drive.
The rebuilding progress will be
displayed (as a percentage) on the LCD.
When rebuild is already started or the
logical drive is being rebuilt by a Local
Spare Drive or Global Spare Drive,
choose “Rebuild Progress” to see the
rebuild progress.
IMPORTANT!
• The Rebuild function will appear only if a logical drive (with
RAID level 1, 3, 5 or 6) has a failed member.
• Carefully verify the physical location of a failed drive before
replacement takes place. Removing the wrong drive may cause a
logical drive to fail and data loss is unrecoverable.
Rebuild Logical
Drive ?
Rebuilding 25%
Please Wait!
LG0 RAID5 DRV=3
2012MB RB SB=0
View and Edit
Logical Drives
LG0 RAID5 DRV=3
2012MB FL SB=0
Rebuild Logical
Drive ..
Rebuild Progress
..