Product specifications

LCD Keypad Operation
2-15
press ENT. “Low” refers to the
temporary default setting.
Press ENT again and the abbreviation
mark “..” will change to a question
mark “?”. Press the up or down arrow
keys to select priority “Low,”
“Normal,” “Improved,” or “High”.
Press ENT to confirm and the question
mark “?” will turn into “
..”.
NOTE:
The rebuild priority determines how much of the system resources are used
when rebuilding a logical drive. The default setting of the rebuild priority is
“Normal.” Rebuild will have less impact on host I/O access, but will take a
longer time to complete. Changing the priority to a higher level will achieve a
faster rebuild, but will significantly increase the host I/O response time. The
default setting “Normal” is recommended.
2.9 Viewing and Editing Logical Drives and
Drive Members
Press ENT for two seconds to enter the
Main Menu. Press the up or down
arrow keys to select "View and Edit
Logical Drives..,” then press ENT.
Press the up or down arrow keys to
select the logical drive, then press ENT.
Press the up or down arrow keys to
select “View Drives..", then press ENT .
Press the up or down arrow keys to
scroll through the list of member
drives.
2.9.1 Deleting a Logical Drive
WARNING!
Rebuild Priority
Low ?
Rebuild Priority
High ..
View and Edit
Logical Drives
LG0 RAID5 DRV=3
2012MB GD SB=1
View Drives
..
Slot=* 1010MB
LG=0 LN SEAGATE