Product specifications
Infortrend
C-28
Message
Peripheral Set 0 Device ALERT: Temperature Sensor 0 Not
Present
What Happens?
Temperature sensor failed or serial bus
configuration/connection faults occurred.
What to Do?
Contact your RAID system supplier.
Message
Peripheral Set 0 Device ALERT: Cold Detected
What Happens?
Temperature dropped below the lower system threshold
detected. Improper installation site condition might have
caused the situation.
What to Do?
Correct your installation site condition. Contact your RAID
system supplier.
Message
SES(C0 I0)Temp Sensor 0: Device Note Supported!
What Happens?
Unrecognizable device type. This event may result from an
incorrect configuration with the SES remote device monitoring.
What to Do?
Check proper module installation and contact your RAID system
supplier.
Message
UPS Connection Is Absent
What Happens?
The COM2 link to a UPS device is absent.
What to Do?
Check cabling to the UPS device. If hardware faults occurred,
contact your RAID system supplier.
Message
SAF-TE Device(2) ALERT: UPS Power Failure Detected
What Happens?
UPS power failure detected through SAF-TE monitoring device.
What to Do?
Contact your UPS supplier.
Message
Peripheral Set 0 Device ALERT: UPS Power Failure Detected
What Happens?
UPS power failure is detected through an I2C serial bus.
What to Do?
Contact your RAID system supplier.
Message
Peripheral Set 0 Device ALERT: UPS 2 AC Power Failure
Detected
What Happens?
AC power source failure reported by UPS and to the subsystem
firmware through an I2C serial bus.
What to Do?
Check your power source connection or contact your RAID
system supplier.
Message
Peripheral Set 0 Device ALERT: UPS 2 Battery Failure Detected
What Happens?
UPS battery failure reported by UPS and to the subsystem
firmware through an I2C serial bus.
What to Do?
Contact your UPS supplier.