C.7 General Target Events
C.7.1 Critical:
Message
SAF-TE Device(0) ALERT: Power Supply Failure
Detected(Idx:132)
What Happens?
Power supply failure detected through SAF-TE monitoring
device.
What to Do?
Contact your RAID supplier for a replacement module.
Message
Peripheral Set 0 Device ALERT: Power Supply 0 Failure Detected
What Happens?
Power supply failure detected through an I2C serial bus.
What to Do?
Contact your RAID supplier for a replacement module.
Message
Peripheral Set 0 Device ALERT: Power Supply 0 Not Present
What Happens?
No power supply module is installed in the expected module
slot.
What to Do?
Check proper module installation. If an installed module can not
be detected, contact your RAID supplier.
Message
Peripheral Set 0 Device ALERT: Low Voltage Detected
(-1073939240.5V)
What Happens?
Low voltage detected from the power supply. Power supply
may have become unstable.
What to Do?
Check proper module installation and contact your RAID
supplier for a replacement module.
Message
SES(C0 I0)Power Supply 0:Device Not Supported!
What Happens?
Unrecognizable device type. This event may result from an
incorrect confi
g
uration with the SES remote device monitorin
g
.
What to Do?
Check proper module installation and contact your RAID system
supplier.
Message
SAF-TE Device(0) ALERT: Cooling Fan Not Installed(Idx:2)
What Happens?
No cooling fan module is installed in the expected module slot.
What to Do?
Check proper module installation. If an installed module can not
be detected, contact your RAID supplier.
Message
SAF-TE Device(0) ALERT: Cooling Fan Failure Detected(Idx:2)
What Happens?
Cooling fan failure detected through SAF-TE monitoring device.
What to Do?
Contact your RAID supplier for a replacement module.
Message
Peripheral Set 0 Device ALERT: Cooling Fan 2 Failure Detected
What Happens?
Cooling fan failure detected through an I2C serial bus.
What to Do?
Contact your RAID supplier for a replacement module.