Product specifications
Infortrend
C-10
Message
LG:0 Logical Drive ALERT: Rebuild Failed
What Happens?
Logical drive rebuild failed. It could result from the one of the
following reasons:
1. The rebuild has been manually canceled by a user.
2. The replacement drive used for a rebuild may have failed
during the rebuild or the drive contains immanent defects.
3. Bad blocks are encountered on another member drive
during the rebuild. (RAID 1, 3, and 5 arrays)
4. System faults occurred.
What to Do?
Carefully identify and replace the faulty drive and perform logical
drive rebuild again. It is best to stop host I/Os temporarily to this
logical drive.
Message
LG:0 Logical Drive ALERT: Parity Regeneration Aborted
What Happens?
System faults or integrity problems forced system to abandon the
operation. Irrecoverable parity inconsistency may also cause a halt
to the operation.
What to Do?
Check proper system working conditions. Contact system vendor
for help.
Message
LG:0 Logical Drive ALERT: Parity Regeneration Failed
What Happens?
System faults or integrity problems forced system to abandon the
operation. Irrecoverable parity inconsistency may also cause a halt
to the operation.
What to Do?
Check proper system working conditions. Contact system vendor
for help.
Message
LG:0 Logical Drive ALERT: Creation Aborted
What Happens?
Logical drive creation process manually aborted or that some
system integrity problems forced the subsystem to abort logical
drive creation process.
What to Do?
Check proper system working conditions.
Message
LG:0 Logical Drive ALERT: Creation Failed
What Happens?
Logical drive creation process failed when one or more drive
members failed or have been accidentally removed. Drive
abnormality may also be the cause of the problems.
What to Do?
Check proper system working conditions and drive connection.
Replace the faulty drives and repeat the creation process.