Product specifications

Event Messages
C-9
Event Description
C.5 Logical Drive Events
C.5.1 Critical:
Message
LG:0 Logical Drive ALERT: CHL:0 ID:132 Drive Missing
What Happens?
The specified hard drive in the specified logical drive has is
missing.
What to Do?
The drive could have been accidentally removed or drive
connection problems occurred. Check drive connection and
related enclosure status.
Message
LG: Logical Drive ALERT: CHL:0 ID:132 Drive Failure
What Happens?
The specified hard drive in the specified logical drive has failed
What to Do?
IF a spare is available, the subsystem will automatically start
rebuild. If there is no spare, replace the faulty drive and rebuild
will be automatically initiated provided that a replacement drive
can be recognized by the subsystem. For example, in a SCSI-based
subsystem, a manual “Scan Drive” command should be executed.
In subsystems using other types of disk drives, drive swap
auto-detection should be enabled on the drive channels.
Message
LG:0 Logical Drive ALERT: Rebuild Aborted
What Happens?
Logical drive rebuild aborted. It could result from the one of the
following reasons:
1. The rebuild has been manually canceled by a user.
2. The replacement drive used for a rebuild may have failed
during the rebuild or the drive contains immanent defects.
3. Bad blocks are encountered on another member drive
during the rebuild. (RAID 1, 3, and 5 arrays)
4. System faults occurred.
What to Do?
Carefully identify and replace the faulty drive and perform logical
drive rebuild again. It is best to stop host I/Os temporarily to this
logical drive.