4.14.1 Mute Beeper
Figure 4 - 69: Mute Beeper Screen
When the subsystem’s beeper (onboard alarm) has been activated, choose
Mute Beeper,” then press [ENTER]. Choose Yes and press [ENTER] in
the next dialog box to turn the beeper off temporarily for the current event.
The beeper will still be activated by the next event.
4.14.2 Change Password
Figure 4 - 70: Change Password Screen
Use the subsystem’s password to protect the array from unauthorized entry.
Once the subsystem password has been set, regardless of whether the front
panel, the RS-232C terminal interface or RAIDWatch Manager is used,
you can only access the subsystem by providing the correct password.
IMPORTANT!
The controller verifies the password when entering the Main
Menu from the initial screen or when making a configuration
change. If the controller is going to be left unattended, the
“Password Validation Timeout” can be set to “Always Check.”
Setting the validation timeout to “Always Check” will protect
the controller configuration from any unauthorized access.
The controller
p
assword and controller name share a 16-