Product specifications
Infortrend
4-34
4.12.3 Identifying Drives
Figure 4 - 56: Identify Drive Page
Whenever there is a failed drive in a logical drive, make it a point to
replace the failed drive with a new, healthy drive to keep the logical
drive working.
If you replaced the wrong drive when trying to replace a failed
drive you will no longer be able to access the logical drive because
you have inadvertently failed another drive.
To prevent this from happening, the controller provides an easy
way to identify the faulty drive. By forcing certain drive LEDs to
light for a configurable period of time, the faulty drive can be
identified, and thus reduce the chance of removing the wrong drive.
This function can be especially helpful in an installation site
operating with hundreds of drives.
4.12.3.1 Flash Selected Drive
The Read/Write LED of the drive you selected will light steadily for
a configurable period of time, from 1 to 999 seconds.
Figure 4 – 57: Flash Selected Drive