Specifications

Symptom Action
System Stops With A 4-Digit Number That Does Not Begin With 0 or 2 Displayed
The system stops and a 4-digit checkpoint that
does not begin with 0 or 2 displayed in the
operator panel display or on the console.
If the number displayed begins with the
characters 8, 9, A,orB, then go to
“Service Processor Checkpoints” on page 79.
If the number displayed is in the range
E1xx-EFFF, make note of any location code
that is displayed on the second line of the
operator panel. If the location code indicates a
card slot (for example, P1-I3), replace the card
in the indicated slot. If this does not correct the
problem, then go to “Firmware Checkpoints” on
page 85.
For all other numbers record SRN 101-xxxx,
where xxxx is the four-digit number displayed
in the operator panel, then go to the
Fast Path
MAP
in
Diagnostic Information for Multiple Bus
Systems
.
Note: If the operator panel displays two sets of
numbers, use the bottom set of numbers as the
error code.
System Stops With A 3-Digit Number Displayed
The system stops and a 3-digit number is
displayed in the operator panel display or on
the console.
Record SRN 101-xxx, where xxx is the 3-digit
number displayed in the operator panel display,
then go to the
Fast Path MAP
in
Diagnostic
Information for Multiple Bus Systems
.
System Stops or Hangs With Alternating Numbers Displayed in the Operator Display Panel
The operator panel display alternates between
the code E1FD and another Exxx code.
Record both codes. Go to “Firmware
Checkpoints” on page 85.
The operator panel display alternates between
the codes E1DE and E1AD.
Record both codes. Go to “Firmware
Checkpoints” on page 85.
There Is a Display Problem (Blank, Distortion, Blurring, Etc.).
40 Service Guide