Specifications
Table 12. Service Request Numbers (continued)
SRN FRU List % Problem
60210 Disk drive module (See “Removing
Hot-Plug SSA Disk Drives” on
page 314.)
100 Description: The disk drive module failed the
diagnostic test.
Action: Exchange the FRU for a new FRU.
60240 Disk drive module (See “Removing
Hot-Plug SSA Disk Drives” on
page 314.)
6-pack assembly (See “Removing
Six-Position SCSI (SES) or SSA Disk
Drive Bays” on page 347.)
98
2
Description: A configuration problem has
occurred. A device cannot be configured, for
some unknown reason.
Action:
1. Replace the disk drive module. If more than
one DASD is suspect, replace it with its
amber check light either blinking or steady.
2. If the problem remains, replace the 6-pack
assembly.
7
xxxx
Disk drive module (See “Removing
Hot-Plug SSA Disk Drives” on
page 314.)
6-pack assembly (See “Removing
Six-Position SCSI (SES) or SSA Disk
Drive Bays” on page 347.)
80
20
Description: A Service Processor module is
missing from the expected configuration of the
SSA loop.
Action: Replace the FRUs one at a time. Go to
″MAP 410: Repair Checkout″ in to verify each
repair.
D0000 Disk drive module (See “Removing
Hot-Plug SSA Disk Drives” on
page 314.)
100 Description: The using system cannot configure
the disk drive module. This is probably a software
problem.
Action:
1. Try again to configure the disk drive module.
2. If the problem remains, go to “Software and
Microcode Errors” on page 411 before
exchanging the FRU.
D0100 Disk drive module (See “Removing
Hot-Plug SSA Disk Drives” on
page 314.)
100 Description: Unable to clear a disk drive module
reservation.
Action: Exchange the FRU for a new FRU.
D0101 Disk drive module (See “Removing
Hot-Plug SSA Disk Drives” on
page 314.)
100 Description: The disk drive module has been
reserved since the diagnostics started. The disk
drive module is in use.
Action: Release the disk drive module, and run
the diagnostics again.
D0200 Disk drive module (See “Removing
Hot-Plug SSA Disk Drives” on
page 314.)
100 Description: The disk drive module timed out
while the diagnostics were running.
Action: Rerun the diagnostics. If the problem
remains, exchange the FRU for a new FRU.
D0300 Disk drive module (See “Removing
Hot-Plug SSA Disk Drives” on
page 314.)
100 Description: The disk drive module failed the
diagnostic test. Action: Exchange the FRU for a
new FRU.
D0400 Disk drive module (See “Removing
Hot-Plug SSA Disk Drives” on
page 314.)
100 Description: The disk drive module is not ready
while the diagnostics are running.
Action: Rerun the diagnostics. If the problem
remains, exchange the FRU for a new FRU.
Appendix F. SSA Software and Microcode Errors
419