Specifications
Table 12. Service Request Numbers (continued)
SRN FRU List % Problem
50100 None – Description: An attempt was made to log an
error against a pdisk that is not available to the
using system.
Action: This problem has occurred for one of the
following reasons:
v A user has deleted a pdisk from the system
configuration. In such an instance, the hdisk
that is related to the pdisk continues to operate
normally. If the disk drive module tries to log an
error, however, this SRN (50100) is produced.
Enter the cfgmgr command to return the pdisk
to the system configuration.
v A disk drive module has tried to log an error
during system configuration. To find the failing
disk drive module, run diagnostics to the disk
drive modules that are connected to this SSA
adapter.
50200
through
504xx
Action: Go to
Advanced SerialRAID Adapters
User’s Guide and Maintenance Information
, order
number SA33-3285.
60000 SSA adapter card (See the
installation guide and the service
guide for the using system.)
100 Description: The SSA adapter is missing from
the expected configuration.
Action: Verify that the SSA adapter card is
installed in the expected slot of the using system.
v If it is in the expected slot, exchange the FRU
for a new FRU.
v If it is not in the expected slot, enter the diag
-a command, and answer the questions that
are displayed.
60200 Disk drive module (See “Removing
Hot-Plug SSA Disk Drives” on
page 314.)
6-pack assembly (See “Removing
Six-Position SCSI (SES) or SSA Disk
Drive Bays” on page 347.)
98
2
Description: The 7133 or other SSA enclosure or
the SSA 6-pack assembly cannot be turned on.
Action:
1. Make sure that power is applied to the 7133
or other SSA enclosure or that the power
cables are properly connected to the SSA
6-pack assembly.
2. Make sure that the Diagnostics questions
were answered correctly before replacing any
of the items in the FRU list. Questions about
the 7133 subsystem power and check light
should have been answered as ″No″ when an
SSA 6-pack assembly is installed in the
system.
3. Replace the disk drive module.
4. If the problem remains, replace the SSA
6-pack assembly.
418 Service Guide