Specifications

Table 12. Service Request Numbers (continued)
SRN FRU List % Problem
46000
through
47500
Action: Go to
Advanced SerialRAID Adapters
User’s Guide and Maintenance Information
, order
number SA33-3285.
48000 None Description: The SSA adapter has detected a
link configuration resource that is not valid.
Action: See “SSA Loop Configurations That Are
Not Valid” on page 420.
48500
through
4BPAA
Action: Go to
Advanced SerialRAID Adapters
User’s Guide and Maintenance Information
, order
number SA33-3285.
50000 SSA adapter card (See the
installation guide and the service
guide for the using system.)
100 Description: The SSA adapter failed to respond
to the device driver.
Action: Exchange the FRU for a new FRU.
50001 SSA adapter card (See the
installation guide and the service
guide for the using system.)
100 Description: A data parity error has occurred.
Action: Exchange the FRU for a new FRU.
50002 SSA adapter card (See the
installation guide and the service
guide for the using system.)
100 Description: An SSA adapter direct memory
access (DMA) error has occurred.
Action: Exchange the FRU for a new FRU.
50004 SSA adapter card (See the
installation guide and the service
guide for the using system.)
100 Description: A channel check has occurred.
Action: Exchange the FRU for a new FRU.
50005 SSA adapter card (See the
installation guide and the service
guide for the using system.)
100 Description: A software error has occurred.
Action: Go to “Software and Microcode Errors”
on page 411 before exchanging the FRU.
50006 SSA adapter card (See the
installation guide and the service
guide for the using system.)
100 Description: A channel check has occurred.
Action: Exchange the FRU for a new FRU.
50007 SSA adapter card (See the
installation guide and the service
guide for the using system.)
100 Description: The input/output channel controller
(IOCC) detected an internal error.
Action: Exchange the FRU for a new FRU.
50008 SSA adapter card (See the
installation guide and the service
guide for the using system.)
100 Description: Unable to read or write the POS
registers.
Action: Exchange the FRU for a new FRU.
50010 SSA adapter card (See the
installation guide and the service
guide for the using system.)
100 Description: An SSA adapter or device drive
protocol error has occurred.
Action: Go to “Software and Microcode Errors”
on page 411 before exchanging the FRU.
50012 SSA adapter card (See the
installation guide and the service
guide for the using system.)
100 Description: The SSA adapter microcode is in a
suspended state.
Action: Run diagnostics in System Verification
mode to the SSA adapter.
v If the diagnostics fail, exchange the FRU for a
new FRU.
v If the diagnostics do not fail, go to “Software
and Microcode Errors” on page 411 before
exchanging the FRU.
Appendix F. SSA Software and Microcode Errors
417