Specifications

Table 12. Service Request Numbers
SRN FRU List % Problem
10101 Disk drive module (See “Removing
Hot-Plug SSA Disk Drives” on
page 314.)
100 Description: Disk drive motor stopped. The disk
drive module is bad.
Action: If this SRN was received by one disk
drive module only, then exchange that disk drive
module.
10112 None Description: Format degraded. A format
operation has been ended before it has
completed.
Action: Use the Format service aid to format the
disk drive module.
1
xxxx
Disk drive module (See “Removing
Hot-Plug SSA Disk Drives” on
page 314.)
100 Description: Disk drive module error.
Action: Exchange the FRU for a new FRU.
Note: In this SRN, an
x
represents a digit from 0
to F.
20PAA Disk drive module (See “Removing
Hot-Plug SSA Disk Drives” on
page 314.)
SSA adapter card (See the
installation guide and the service
guide for the using system.)
External SSA Cables
6-pack assembly (See “Removing
Six-Position SCSI (SES) or SSA Disk
Drive Bays” on page 347.)
Internal SSA Cable
45
45
6
2
2
Description: An open SSA link has been
detected.
Action: Run the Link Verification Service Aid to
isolate the failure. If the SSA service aids are not
available:
v When the failing device is an SSA hot-swap
disk drive, go to “SSA Maintenance Analysis
Procedures (MAPs)” on page 70.
v When the failing device is not an SSA
hot-swap disk drive, go to the service
information for that device.
21PAA
to
29PAA
Disk drive module (See “Removing
Hot-Plug SSA Disk Drives” on
page 314.)
SSA adapter card (See the
installation guide and the service
guide for the using system.)
External SSA Cables
6-pack assembly (See “Removing
Six-Position SCSI (SES) or SSA Disk
Drive Bays” on page 347.)
Internal SSA Cable
45
45
6
2
2
Description: An SSA threshold-exceeded-link
error has been detected.
Action: Run the Link Verification Service Aid to
isolate the failure. If the SSA service aids are not
available:
v When the failing device is an SSA hot-swap
disk drive, go to “SSA Maintenance Analysis
Procedures (MAPs)” on page 70.
v When the failing device is not an SSA
hot-swap disk drive, go to the service
information for that device.
2A002 Disk drive module (See “Removing
Hot-Plug SSA Disk Drives” on
page 314.)
SSA adapter card (See the
installation guide and the service
guide for the using system.)
50
50
Description: Async code 02 has been received.
A software error has probably occurred.
Action: Go to “Software and Microcode Errors”
on page 411 before exchanging any FRUs.
2A003 Disk drive module (See “Removing
Hot-Plug SSA Disk Drives” on
page 314.)
SSA adapter card (See the
installation guide and the service
guide for the using system.)
50
50
Description: Async code 03 has been received.
A software error has probably occurred.
Action: Go to “Software and Microcode Errors”
on page 411 before exchanging any FRUs.
Appendix F. SSA Software and Microcode Errors
413