Specifications
Problem Determination-Generated Error Codes
Attention: If you replace FRUs or perform an action and the problem is still not
corrected, go to “MAP 1540: Minimum Configuration” on page 52 unless otherwise
indicated in the tables.
If you replace FRUs or perform an action and the problem is corrected, go to ″MAP
410: Repair Checkout″ in
Diagnostic Information for Multiple Bus Systems
.
Note: Do not shut down the system if the FRU was replaced by hot swap.
Table 11. Problem Determination Generated Error Codes
Error Code Description Action/ Possible Failing FRU
M0BT 0000 The system hung during speaker
POST. This error code is generated
by the customer performing “Problem
Determination” in the
26F/80, 256/F0,
and 256/F1 User’s Guide
.
Go to “MAP 1540: Minimum
Configuration” on page 52.
M0BT 0001 The system hung during “Starting
Software...”. This error code is
generated by the customer
performing “Problem Determination”
in the
26F/80, 256/F0, and 256/F1
User’s Guide
.
Go to “MAP 1540: Minimum
Configuration” on page 52.
M0KB D000 The system hung during keyboard
POST. This error code is generated
by the customer performing “Problem
Determination” in the
26F/80, 256/F0,
and 256/F1 User’s Guide
.
Keyboard
M0KB D001 The system did not respond to a
keyboard entry. This error code is
generated by the customer
performing “Problem Determination”
in the
26F/80, 256/F0, and 256/F1
User’s Guide
.
Type 101 keyboard.
M0KB D002 The system did not respond to a
keyboard entry. This error code is
generated by the customer
performing “Problem Determination”
in the
26F/80, 256/F0, and 256/F1
User’s Guide
.
Type 102 keyboard.
M0KB D003 The system did not respond to a
keyboard entry. This error code is
generated by the customer
performing “Problem Determination”
in the
26F/80, 256/F0, and 256/F1
User’s Guide
.
Kanji-type keyboard.
Chapter 5. Error Code to FRU Index
241