Table 9. Common Firmware Error Codes (continued)
Error Code Description Action/ Possible Failing FRU
B1xx 4691 System firmware surveillance time
out (System firmware to service
processor interface failure)
1. Check for system firmware
updates
2. Go to the service processor main
menu and select System
Information Menu, then select
Read Progress Indicators from
Last System Boot. Begin your
repair action with the error code
or checkpoint immediately
preceding B1xx 4691. If a
location code appears with the
error code or checkpoint, replace
the part at that location. If no
location code is specified, and
you have an 8-character error
code, go to “Firmware
Checkpoints” on page 85. If no
location code is specified and you
have a 4-character checkpoint, go
to “Checkpoint and Error Code
Index” on page 100.
3. If the problem is not resolved, call
service support.
B1xx 4692 Operator panel task interface failure 1. Check for system firmware
updates, Location: P1/Y1
2. If the problem is not solved, call
service support.
B1xx 4693 Service processor firmware error 1. Check for system firmware
updates
2. The type and model field in the
VPD module may be set
incorrectly. The type and model
field can be viewed using the
service processor function Read
VPD Image from Last System
Boot, which is option 1 in the
“System Information Menu” on
page 258. If the type and model
field is not set correctly, call
service support.
3. Call service support
B1xx 4694 Service processor firmware failure
1. Check for system firmware
updates
2. System board, Location: P1 (See
note 3 on page 37.)
B1xx 4695 System power control network to
service processor interface failure
1. Check for system firmware
updates
2. System board, Location: P1 (See
note 3 on page 37.)