Specifications
Table 9. Common Firmware Error Codes (continued)
Error Code Description Action/ Possible Failing FRU
B1xx 4645 Non-processor VPD failure Ignore all location codes.
Go to MAP 1540: Minimum
Configuration.
B1xx 4646 General VPD failure Ignore all location codes.
Go to MAP 1540: Minimum
Configuration.
B1xx 4647 The machine type and model
reported by the CEC hardware do not
match the machine type and model
stored in the VPD module on the
operator panel.
Replace the operator panel, Location:
L1. Do not swap the VPD module
from the old op panel onto the new
op panel; leave the new,
unprogrammed VPD module on the
new op panel. Call service support to
get instructions on reprogramming
the machine type and model and the
system serial number in the VPD
module.
B1xx 4648 CPU backplane VPD failure Ignore all location codes.
Go to MAP 1540: Minimum
Configuration.
B1xx 4650 A system processor failure has been
detected by the service processor. All
system processors have been reset
in an attempt to recover operations.
Information only. If the problem
persists, check the error logs for
other fault indications.
If no other fault indications are found,
go to “MAP 1540: Minimum
Configuration” on page 52 and run
the minimum configuration.
B1xx 4651 CPU VPD fault Processor card, Location: P1-C1
B1xx 4660 Memory subsystem failure (cannot
isolate)
Go to “MAP 1540: Minimum
Configuration” on page 52
B1xx 4661 Memory riser card VPD failure Go to “MAP 1540: Minimum
Configuration” on page 52
B1xx 4662 Memory DIMM VPD failure Go to “MAP 1540: Minimum
Configuration” on page 52
B1xx 4670 Processor cooling 1. Check ambient temperature
2. Check air supply to fans
3. Check fans for proper installation
and operation
4. Check for unsupported cards
(that may be too hot)
5. Operator panel, Location: L1
Chapter 5. Error Code to FRU Index
237