Specifications
Table 9. Common Firmware Error Codes (continued)
Error Code Description Action/ Possible Failing FRU
B10F 1681 Service processor firmware update
invalid
Call service support
B10F 1682 Service processor firmware update
invalid
Call service support
B10F 1683 Service processor firmware update
invalid
Call service support
B1FD 0013 A firmware update has failed because
the update image is invalid. The
update was aborted before any
changes were made to the currently
installed firmware.
Reset the service processor (by
activating the pinhole reset switch or
by disconnecting then reconnecting
power). Install a valid firmware
update image for the specific system
type and model.
B1FD 0015 Too many firmware update diskettes
inserted (or wrong or faulty update
image)
1. Ensure that the firmware update
image is correct for the specific
system type and model.
2. Replace the update diskettes with
a new set of firmware update
diskettes.
B1FD 0016 Diskette read error 1. The firmware diskette may be
faulty. Try another diskette.
2. Replace the diskette drive.
3. Replace the system board
Location: P1
B1FD 001A Service processor recovery mode
update fault
Reset the service processor by
activating the pinhole reset switch or
by disconnecting and then
reconnecting the power.
B1FD 001E Service processor recovery mode
update fault
Wrong firmware update diskette.
Insert correct diskette.
B1FD 001F Bad firmware update diskette Replace diskette
B1xx 0013 A firmware update has failed because
the update image is invalid. The
update was aborted before any
changes were made to the currently
installed firmware.
Install a valid firmware update image
for the specific system type and
model.
B1xx 4600 Service processor failure System board, Location: P1
B1xx 4601 System processor subsystem Go to “MAP 1540: Minimum
Configuration” on page 52
B1xx 4602 RIO subsystem failure 1. Processor card, Location: P1-C1
2. Replace the system board,
Location: P1 (See note 3 on
page 37.)
B1xx 4603 Service processor firmware corrupted 1. Reload system firmware
2. Replace the system board,
Location: P1 (See note 3 on
page 37.)
Chapter 5. Error Code to FRU Index