Specifications
Table 7. Service Processor Error Codes (continued)
Error Code Description Action/ Possible Failing FRU
4B2C 263D Processor system and IPL detected
memory filler fault
Memory filler card, Location: P1-M1
or P1-M2
4B2C 281F Processor system and IPL detected
SSA backplane fault
SSA 6-pack, Location: B1 or B2
4B2C 282E Processor system and IPL detected
system board fault
1. System board, Location: P1
2. Processor card, Location: P1-C1
4B2C 283F Processor system and IPL detected
SCSI backplane fault
SCSI 6-pack, Location: B1 or B2
4B2C 288D Processor system and IPL detected
memory riser fault
Memory riser card, Location: P1-M1
or P1-M2
4B2C 2A00 Processor system and IPL detected
6W 4M 500 MHz processor fault
Processor card, Location: P1-C1
4B2C 300A Processor system and IPL detected
32MB DIMM fault
Memory DIMM, Location: P1-M1.n or
P1-M2.n or P1-C1-Mn
4B2C 300B Processor system and IPL detected
128MB DIMM fault
Memory DIMM, Location: P1-M1.n or
P1-M2.n or P1-C1-Mn
4B2C 300C Processor system and IPL detected
256MB DIMM fault
Memory DIMM, Location: P1-M1.n or
P1-M2.n or P1-C1-Mn
4B2C 300D Processor system and IPL detected
512MB (stacked) DIMM fault
Memory DIMM, Location: P1-M1.n or
P1-M2.n or P1-C1-Mn
4B2C 300E Processor system and IPL detected
512MB (unstacked) DIMM fault
Memory DIMM, Location: P1-M1.n or
P1-M2.n or P1-C1-Mn
4B2C 301F Processor system and IPL detected
128MB DIMM fault
Memory DIMM, Location: P1-M1.n or
P1-M2.n or P1-C1-Mn
4B2C 303A Processor system and IPL detected
1GB DIMM fault
Memory DIMM, Location: P1-M1.n or
P1-M2.n or P1-C1-Mn
4B2D 244C Processor system and attention
handler detected 1W 2M 400 MHz
processor fault
Processor card, Location: P1-C1
4B2D 244D Processor system and attention
handler detected 2W 4M 500 MHz
processor fault
Processor card, Location: P1-C1
4B2D 244E Processor system and attention
handler detected 4W 4M 500 MHz
processor fault
Processor card, Location: P1-C1
4B2D 244F Processor system and attention
handler detected 1W 2M 500 MHz
processor fault
Processor card, Location: P1-C1
4B2D 248A Processor system and attention
handler detected operator panel fault
Operator panel, Location : L1
4B2D 24A1 Processor system and attention
handler detected 1W 2M 450 MHz
processor fault
Processor card, Location: P1-C1
Chapter 5. Error Code to FRU Index
227