Table 7. Service Processor Error Codes (continued)
Error Code Description Action/ Possible Failing FRU
4B2B 25BB Processor system and wire test
detected 1W 600 MHz processor
fault
Processor card, Location: P1-C1
4B2B 25BD Processor system and wire test
detected 2W 600 MHz processor
fault
Processor card, Location: P1-C1
4B2B 25BE Processor system and wire test
detected 4W 600 MHz processor
fault
Processor card, Location: P1-C1
4B2B 25BF Processor system and wire test
detected 6W 668 MHz processor
fault
Processor card, Location: P1-C1
4B2B 25CB 1W processor card fault Replace the processor card,
Location: P1-C1
4B2B 25EA 4W processor card fault Replace the processor card,
Location: P1-C1
4B2B 25EB 2W processor card fault Replace the processor card,
Location: P1-C1
4B2B 25F2 6W processor card fault Replace the processor card,
Location: P1-C1
4B2B 263D Processor system and wire test
detected memory filler fault
Memory filler card, Location: P1-M1
or P1-M2
4B2B 281F Processor system and wire test
detected SSA backplane fault
SSA 6-pack, Location: B1 or B2
4B2B 282E Processor system and wire test
detected system board fault
1. System board, Location: P1
2. Processor card, Location: P1-C1
4B2B 283F Processor system and wire test
detected SCSI backplane fault
SCSI 6-pack, Location: B1 or B2
4B2B 288D Processor system and wire test
detected memory riser fault
Memory riser card, Location: P1-M1
or P1-M2
4B2B 2A00 Processor system and wire test
detected 6W 4M 500 MHz processor
fault
Processor card, Location: P1-C1
4B2B 300A Processor system and wire test
detected 32MB DIMM fault
Memory DIMM, Location: P1-M1.n or
P1-M2.n or P1-C1-Mn
4B2B 300B Processor system and wire test
detected 128MB DIMM fault
Memory DIMM, Location: P1-M1.n or
P1-M2.n or P1-C1-Mn
4B2B 300C Processor system and wire test
detected 256MB DIMM fault
Memory DIMM, Location: P1-M1.n or
P1-M2.n or P1-C1-Mn
4B2B 300D Processor system and wire test
detected 512MB (stacked) DIMM
fault
Memory DIMM, Location: P1-M1.n or
P1-M2.n or P1-C1-Mn
Chapter 5. Error Code to FRU Index