Specifications

Table 7. Service Processor Error Codes (continued)
Error Code Description Action/ Possible Failing FRU
4B28 24A2 Processor system and other bus
processor runtime diagnostics
detected 2W 450 MHz processor
fault
Processor card, Location: P1-C1
4B28 24A3 Processor system and other bus
processor runtime diagnostics
detected 4W 450 MHz processor
fault
Processor card, Location: P1-C1
4B28 24A4 Processor system and other bus
processor runtime diagnostics
detected 6W 500 MHz processor
fault
Processor card, Location: P1-C1
4B28 25B6 Processor system and other bus
processor runtime diagnostics
detected 650W power supply fault
Power supply Location: V1 or V2 or
V3
4B28 25BB Processor system and other bus
processor runtime diagnostics
detected 1W 600 MHz processor
fault
Processor card, Location: P1-C1
4B28 25BD Processor system and other bus
processor runtime diagnostics
detected 2W 600 MHz processor
fault
Processor card, Location: P1-C1
4B28 25BE Processor system and other bus
processor runtime diagnostics
detected 4W 600 MHz processor
fault
Processor card, Location: P1-C1
4B28 25BF Processor system and other bus
processor runtime diagnostics
detected 6W 668 MHz processor
fault
Processor card, Location: P1-C1
4B28 25CB 1W processor card fault Replace the processor card,
Location: P1-C1
4B28 25EA 4W processor card fault Replace the processor card,
Location: P1-C1
4B28 25EB 2W processor card fault Replace the processor card,
Location: P1-C1
4B28 25F2 6W processor card fault Replace the processor card,
Location: P1-C1
4B28 263D Processor system and other bus
processor runtime diagnostics
detected memory filler fault
Memory filler card, Location: P1-M1
or P1-M2
4B28 281F Processor system and other bus
processor runtime diagnostics
detected SSA backplane fault
SSA 6-pack, Location: B1 or B2
Chapter 5. Error Code to FRU Index
219