Specifications

Table 7. Service Processor Error Codes (continued)
Error Code Description Action/ Possible Failing FRU
460D 25BB I/O system and attention handler
detected 1W 600 MHz processor
fault
Processor card, Location: P1-C1
460D 25BD I/O system and attention handler
detected 2W 600 MHz processor
fault
Processor card, Location: P1-C1
460D 25BE I/O system and attention handler
detected 4W 600 MHz processor
fault
Processor card, Location: P1-C1
460D 25BF I/O system and attention handler
detected 6W 668 MHz processor
fault
Processor card, Location: P1-C1
460D 263D I/O system and attention handler
detected memory filler fault
Memory filler card, Location: P1-M1
or P1-M2
460D 281F I/O system and attention handler
detected SSA backplane fault
SSA 6-pack, Location: B1 or B2
460D 282E I/O system and attention handler
detected system board fault
1. System board, Location: P1
2. Processor card, Location: P1-C1
460D 283F I/O system and attention handler
detected SCSI backplane fault
SCSI 6-pack, Location: B1 or B2
460D 288D I/O system and attention handler
detected memory riser fault
Memory riser card, Location: P1-M1
or P1-M2
460D 2A00 I/O system and attention handler
detected 6W 4M 500 MHz processor
fault
Processor card, Location: P1-C1
460D 300A I/O system and attention handler
detected 32MB DIMM fault
Memory DIMM, Location: P1-M1.n or
P1-M2.n or P1-C1-Mn
460D 300B I/O system and attention handler
detected 128MB DIMM fault
Memory DIMM, Location: P1-M1.n or
P1-M2.n or P1-C1-Mn
460D 300C I/O system and attention handler
detected 256MB DIMM fault
Memory DIMM, Location: P1-M1.n or
P1-M2.n or P1-C1-Mn
460D 300D I/O system and attention handler
detected 512MB (stacked) DIMM
fault
Memory DIMM, Location: P1-M1.n or
P1-M2.n or P1-C1-Mn
460D 300E I/O system and attention handler
detected 512MB (unstacked) DIMM
fault
Memory DIMM, Location: P1-M1.n or
P1-M2.n or P1-C1-Mn
460D 301F I/O system and attention handler
detected 128MB DIMM fault
Memory DIMM, Location: P1-M1.n or
P1-M2.n or P1-C1-Mn
460D 303A I/O system and attention handler
detected 1GB DIMM fault
Memory DIMM, Location: P1-M1.n or
P1-M2.n or P1-C1-Mn
460E 244C I/O system and scan control routines
detected 1W 2M 400 MHz processor
fault
Processor card, Location: P1-C1
210 Service Guide