Specifications
Table 7. Service Processor Error Codes (continued)
Error Code Description Action/ Possible Failing FRU
460B 24A1 I/O system and wire test detected 1W
2M 450 MHz processor fault
Processor card, Location: P1-C1
460B 24A2 I/O system and wire test detected 2W
450 MHz processor fault
Processor card, Location: P1-C1
460B 24A3 I/O system and wire test detected 4W
450 MHz processor fault
Processor card, Location: P1-C1
460B 24A4 I/O system and wire test detected 6W
500 MHz processor fault
Processor card, Location: P1-C1
460B 25B6 I/O system and wire test detected
650W power supply fault
Power supply Location: V1 or V2 or
V3
460B 25BB I/O system and wire test detected 1W
600 MHz processor fault
Processor card, Location: P1-C1
460B 25BD I/O system and wire test detected 2W
600 MHz processor fault
Processor card, Location: P1-C1
460B 25BE I/O system and wire test detected 4W
600 MHz processor fault
Processor card, Location: P1-C1
460B 25BF I/O system and wire test detected 6W
668 MHz processor fault
Processor card, Location: P1-C1
460B 263D I/O system and wire test detected
memory filler fault
Memory filler card, Location: P1-M1
or P1-M2
460B 281F I/O system and wire test detected
SSA backplane fault
SSA 6-pack, Location: B1 or B2
460B 282E I/O system and wire test detected
system board fault
1. System board, Location: P1
2. Processor card, Location: P1-C1
460B 283F I/O system and wire test detected
SCSI backplane fault
SCSI 6-pack, Location: B1 or B2
460B 288D I/O system and wire test detected
memory riser fault
Memory riser card, Location: P1-M1
or P1-M2
460B 2A00 I/O system and wire test detected 6W
4M 500 MHz processor fault
Processor card, Location: P1-C1
460B 300A I/O system and wire test detected
32MB DIMM fault
Memory DIMM, Location: P1-M1.n or
P1-M2.n or P1-C1-Mn
460B 300B I/O system and wire test detected
128MB DIMM fault
Memory DIMM, Location: P1-M1.n or
P1-M2.n or P1-C1-Mn
460B 300C I/O system and wire test detected
256MB DIMM fault
Memory DIMM, Location: P1-M1.n or
P1-M2.n or P1-C1-Mn
460B 300D I/O system and wire test detected
512MB (stacked) DIMM fault
Memory DIMM, Location: P1-M1.n or
P1-M2.n or P1-C1-Mn
460B 300E I/O system and wire test detected
512MB (unstacked) DIMM fault
Memory DIMM, Location: P1-M1.n or
P1-M2.n or P1-C1-Mn
460B 301F I/O system and wire test detected
128MB DIMM fault
Memory DIMM, Location: P1-M1.n or
P1-M2.n or P1-C1-Mn
Chapter 5. Error Code to FRU Index