Specifications
Table 7. Service Processor Error Codes (continued)
Error Code Description Action/ Possible Failing FRU
4607 24A2 I/O system and 6xx bus processor
runtime diagnostics detected 2W 450
MHz processor fault
Processor card, Location: P1-C1
4607 24A3 I/O system and 6xx bus processor
runtime diagnostics detected 4W 450
MHz processor fault
Processor card, Location: P1-C1
4607 24A4 I/O system and 6xx bus processor
runtime diagnostics detected 6W 500
MHz processor fault
Processor card, Location: P1-C1
4607 25B6 I/O system and 6xx bus processor
runtime diagnostics detected 650W
power supply fault
Power supply Location: V1 or V2 or
V3
4607 25BB I/O system and 6xx bus processor
runtime diagnostics detected 1W 600
MHz processor fault
Processor card, Location: P1-C1
4607 25BD I/O system and 6xx bus processor
runtime diagnostics detected 2W 600
MHz processor fault
Processor card, Location: P1-C1
4607 25BE I/O system and 6xx bus processor
runtime diagnostics detected 4W 600
MHz processor fault
Processor card, Location: P1-C1
4607 25BF I/O system and 6xx bus processor
runtime diagnostics detected 6W 668
MHz processor fault
Processor card, Location: P1-C1
4607 263D I/O system and 6xx bus processor
runtime diagnostics detected memory
filler fault
Memory filler card, Location: P1-M1
or P1-M2
4607 281F I/O system and 6xx bus processor
runtime diagnostics detected SSA
backplane fault
SSA 6-pack, Location: B1 or B2
4607 282E I/O system and 6xx bus processor
runtime diagnostics detected system
board fault
1. System board, Location: P1
2. Processor card, Location: P1-C1
4607 283F I/O system and 6xx bus processor
runtime diagnostics detected SCSI
backplane fault
SCSI 6-pack, Location: B1 or B2
4607 288D I/O system and 6xx bus processor
runtime diagnostics detected memory
riser fault
Memory riser card, Location: P1-M1
or P1-M2
4607 2A00 I/O system and 6xx bus processor
runtime diagnostics detected 6W 4M
500 MHz processor fault
Processor card, Location: P1-C1
4607 300A I/O system and 6xx bus processor
runtime diagnostics detected 32MB
DIMM fault
Memory DIMM, Location: P1-M1.n or
P1-M2.n or P1-C1-Mn
Chapter 5. Error Code to FRU Index
201