Table 7. Service Processor Error Codes (continued)
Error Code Description Action/ Possible Failing FRU
450E 24A1 Memory system and scan control
routines detected 1W 2M 450 MHz
processor fault
Processor card, Location: P1-C1
450E 24A2 Memory system and scan control
routines detected 2W 450 MHz
processor fault
Processor card, Location: P1-C1
450E 24A3 Memory system and scan control
routines detected 4W 450 MHz
processor fault
Processor card, Location: P1-C1
450E 24A4 Memory system and scan control
routines detected 6W 500 MHz
processor fault
Processor card, Location: P1-C1
450E 25B6 Memory system and scan control
routines detected 650W power supply
fault
Power supply, Location: V1 or V2 or
V3
450E 25BB Memory system and scan control
routines detected 1W 600 MHz
processor fault
Processor card, Location: P1-C1
450E 25BD Memory system and scan control
routines detected 2W 600 MHz
processor fault
Processor card, Location: P1-C1
450E 25BE Memory system and scan control
routines detected 4W 600 MHz
processor fault
Processor card, Location: P1-C1
450E 25BF Memory system and scan control
routines detected 6W 668 MHz
processor fault
Processor card, Location: P1-C1
450E 25CB 1W processor card fault Replace the processor card,
Location: P1-C1
450E 25EA 4W processor card fault Replace the processor card,
Location: P1-C1
450E 25EB 2W processor card fault Replace the processor card,
Location: P1-C1
450E 25F2 6W processor card fault Replace the processor card,
Location: P1-C1
450E 263D Memory system and scan control
routines detected memory filler fault
Memory filler card, Location: P1-M1
or P1-M2
450E 281F Memory system and scan control
routines detected SSA backplane
fault
SSA 6-pack, Location: B1 or B2
450E 282E Memory system and scan control
routines detected system board fault
1. System board, Location: P1
2. Processor card, Location: P1-C1
450E 283F Memory system and scan control
routines detected SCSI backplane
fault
SCSI 6-pack, Location: B1 or B2
Chapter 5. Error Code to FRU Index