Specifications
Table 7. Service Processor Error Codes (continued)
Error Code Description Action/ Possible Failing FRU
4508 25CB 1W processor card fault Replace the processor card,
Location: P1-C1
4508 25EA 4W processor card fault Replace the processor card,
Location: P1-C1
4508 25EB 2W processor card fault Replace the processor card,
Location: P1-C1
4508 25F2 6W processor card fault Replace the processor card,
Location: P1-C1
4508 263D Memory system and other bus
processor runtime diagnostics
detected memory filler fault
Memory filler card, Location: P1-M1
or P1-M2
4508 281F Memory system and other bus
processor runtime diagnostics
detected SSA backplane fault
SSA 6-pack, Location: B1 or B2
4508 282E Memory system and other bus
processor runtime diagnostics
detected system board fault
Replace the system board. Location:
P1 (See note 3 on page 37.)
4508 283F Memory system and other bus
processor runtime diagnostics
detected SCSI backplane fault
SCSI 6-pack, Location: B1 or B2
4508 288D Memory system and other bus
processor runtime diagnostics
detected memory riser fault
1. If more than one DIMM is called
out, go to the service processor
Memory
Configuration/Deconfiguration
Menu to verify memory DIMMs
state. See ″Memory
Configuration/Deconfiguration
Menu″ on page 260 for more
information.
2. Memory riser card, Location:
P1-M1 or P1-M2
4508 2A00 Memory system and other bus
processor runtime diagnostics
detected 6W 4M 500 MHz processor
fault
Processor card, Location: P1-C1
4508 300A Memory system and other bus
processor runtime diagnostics
detected 32MB DIMM fault
Memory DIMM, Location: P1-M1.n or
P1-M2.n or P1-C1-Mn
4508 300B Memory system and other bus
processor runtime diagnostics
detected 128MB DIMM fault
Memory DIMM, Location: P1-M1.n or
P1-M2.n or P1-C1-Mn
4508 300C Memory system and other bus
processor runtime diagnostics
detected 256MB DIMM fault
Memory DIMM, Location: P1-M1.n or
P1-M2.n or P1-C1-Mn
184 Service Guide