Specifications

Table 7. Service Processor Error Codes (continued)
Error Code Description Action/ Possible Failing FRU
406E 00A6 Scan control routines detected no
usable memory
1. Ensure that memory is properly
installed
2. If more than one DIMM is called
out, go to the service processor
Memory
Configuration/Deconfiguration
Menu to verify memory DIMMs
state. See Memory
Configuration/Deconfiguration
Menu on page 260 for more
information.
3. Go to “MAP 1540: Minimum
Configuration” on page 52
4. If the problem is not fixed, call
service support.
406E 00A7 Scan control routines detected
hardware problem
Go to “MAP 1540: Minimum
Configuration” on page 52.
406E 00B0 Scan control routines detected bus
controller lock-unlock failure
System board, Location: P1
406E 00B1 Scan control routines detected bus
controller failure
System board, Location: P1
406E 00B7 Scan control routines detected
insufficient hardware resources to
continue IPL
This error code appears after the
initial testing by the service processor
firmware on the processors and
memory completed successfully, but
a problem occurred when the
firmware tried to communicate
outside the processor and memory
complex. Suspect a problem with the
backplane, location: P1.
406E 0100 Scan control routines detected
memory riser card fault
Memory riser card Location: P1-M2
406E 0101 Scan control routines detected
memory DIMM fault
Memory DIMM Location: P1-M2.15
406E 0102 Scan control routines detected
memory DIMM fault
Memory DIMM Location: P1-M2.1
406E 0103 Scan control routines detected
memory DIMM fault
Memory DIMM Location: P1-M2.16
406E 0104 Scan control routines detected
memory DIMM fault
Memory DIMM Location: P1-M2.2
406E 010D Scan control routines detected
memory DIMM fault
Memory DIMM Location: P1-M2.1 x4
406E 0111 Scan control routines detected
memory DIMM fault
Memory DIMM Location: P1-M2.13
406E 0112 Scan control routines detected
memory DIMM fault
Memory DIMM Location: P1-M2.3