Specifications

Table 7. Service Processor Error Codes (continued)
Error Code Description Action/ Possible Failing FRU
406D 00A7 Attention handler detected hardware
problem
Go to “MAP 1540: Minimum
Configuration” on page 52.
406D 00B0 Attention handler detected bus
controller lock-unlock failure
System board, Location: P1
406D 00B1 Attention handler diagnostics
detected bus controller failure
System board, Location: P1
406D 00B7 Attention handler detected insufficient
hardware resources to continue IPL
This error code appears after the
initial testing by the service processor
firmware on the processors and
memory completed successfully, but
a problem occurred when the
firmware tried to communicate
outside the processor and memory
complex. Suspect a problem with the
backplane, location: P1.
406D 0100 Attention handler detected memory
riser card fault
Memory riser card Location: P1-M2
406D 0101 Attention handler detected memory
DIMM fault
Memory DIMM Location: P1-M2.15
406D 0102 Attention handler detected memory
DIMM fault
Memory DIMM Location: P1-M2.1
406D 0103 Attention handler detected memory
DIMM fault
Memory DIMM Location: P1-M2.16
406D 0104 Attention handler detected memory
DIMM fault
Memory DIMM Location: P1-M2.2
406D 010D Attention handler detected memory
DIMM fault
Memory DIMM Location: P1-M2.1 x4
406D 0111 Attention handler detected memory
DIMM fault
Memory DIMM Location: P1-M2.13
406D 0112 Attention handler detected memory
DIMM fault
Memory DIMM Location: P1-M2.3
406D 0113 Attention handler detected memory
DIMM fault
Memory DIMM Location: P1-M2.14
406D 0114 Attention handler detected memory
DIMM fault
Memory DIMM Location: P1-M2.4
406D 011D Attention handler detected memory
DIMM fault
Memory DIMM Location: P1-M2.3 x4
406D 0121 Attention handler detected memory
DIMM fault
Memory DIMM Location: P1-M2.11
406D 0122 Attention handler detected memory
DIMM fault
Memory DIMM Location: P1-M2.5
406D 0123 Attention handler detected memory
DIMM fault
Memory DIMM Location: P1-M2.12