Table 7. Service Processor Error Codes (continued)
Error Code Description Action/ Possible Failing FRU
406C 023D IPL MOPs detected memory DIMM
fault
Memory DIMM Location: P1-M1.7 x4
406C 02FF IPL MOPs detected memory failure
on riser card 1 that cannot be
automatically isolated.
Go to “MAP 1540: Minimum
Configuration” on page 52, and run
minimum configuration for further
isolation.
406C 0300 IPL MOPs detected processor card
fault
Processor card Location: P1-C1
Note: If this error occurs on a Model
6F0Model 256/F0, first verify that the
correct type of processor card is
installed in the system. Up to four
processors are supported in a Model
6F0Model 256/F0 system; if a 6-way
processor is plugged into the system,
this error code will be generated and
the system will not boot.
406C 0301 IPL MOPs detected memory DIMM
fault
Memory DIMM Location: P1-C1-M8
406C 0302 IPL MOPs detected memory DIMM
fault
Memory DIMM Location: P1-C1-M1
406C 030D IPL MOPs detected memory DIMM
fault
Memory DIMM Location: P1-C1-M1
x2
406C 0311 IPL MOPs detected memory DIMM
fault
Memory DIMM Location: P1-C1-M7
406C 0312 IPL MOPs detected memory DIMM
fault
Memory DIMM Location: P1-C1-M2
406C 031D IPL MOPs detected memory DIMM
fault
Memory DIMM Location: P1-C1-M2
x2
406C 0321 IPL MOPs detected memory DIMM
fault
Memory DIMM Location: P1-C1-M6
406C 0322 IPL MOPs detected memory DIMM
fault
Memory DIMM Location: P1-C1-M3
406C 032D IPL MOPs detected memory DIMM
fault
Memory DIMM Location: P1-C1-M3
x2
406C 0331 IPL MOPs detected memory DIMM
fault
Memory DIMM Location: P1-C1-M5
406C 0332 IPL MOPs detected memory DIMM
fault
Memory DIMM Location: P1-C1-M4
406C 033D IPL MOPs detected memory DIMM
fault
Memory DIMM Location: P1-C1-M4
x2
406C 03FF IPL MOPs detected memory failure
on processor card that cannot be
automatically isolated.
Go to “MAP 1540: Minimum
Configuration” on page 52, and run
minimum configuration for further
isolation.
164 Service Guide