Specifications

Table 7. Service Processor Error Codes (continued)
Error Code Description Action/ Possible Failing FRU
406B 030D Wire tests detected memory DIMM
fault
Memory DIMM Location: P1-C1-M1
x2
406B 0311 Wire tests detected memory DIMM
fault
Memory DIMM Location: P1-C1-M7
406B 0312 Wire tests detected memory DIMM
fault
Memory DIMM Location: P1-C1-M2
406B 031D Wire tests detected memory DIMM
fault
Memory DIMM Location: P1-C1-M2
x2
406B 0321 Wire tests detected memory DIMM
fault
Memory DIMM Location: P1-C1-M6
406B 0322 Wire tests detected memory DIMM
fault
Memory DIMM Location: P1-C1-M3
406B 032D Wire tests detected memory DIMM
fault
Memory DIMM Location: P1-C1-M3
x2
406B 0331 Wire tests detected memory DIMM
fault
Memory DIMM Location: P1-C1-M5
406B 0332 Wire tests detected memory DIMM
fault
Memory DIMM Location: P1-C1-M4
406B 033D Wire tests detected memory DIMM
fault
Memory DIMM Location: P1-C1-M4
x2
406B 03FF Wire tests detected memory failure
on processor card that cannot be
automatically isolated.
Go to “MAP 1540: Minimum
Configuration” on page 52, and run
minimum configuration for further
isolation.
406B 3101 Wire tests detected RIO port 0 fault 1. RIO port 0, Location: P1-C1
2. System board, Location: P1
406B 3281 Wire tests detected RIO port 0 fault 1. RIO port 0, Location: P1-C1
2. System board, Location: P1
406B 3284 Wire tests detected PCI controller
PHB0 fault
Replace the system board. Location:
P1 (See note 3 on page 37.)
406B 3285 Wire tests detected PCI controller
PHB1 fault
Replace the system board. Location:
P1 (See note 3 on page 37.)
406B 3286 Wire tests detected PCI controller
PHB2 fault
Replace the system board. Location:
P1 (See note 3 on page 37.)
406C 0001 IPL MOPs detected system board
fault
Replace the system board. Location:
P1 (See note 3 on page 37.)
406C 0003 IPL MOPs detected processor fault All processors, Location: P1-C1
406C 0009 IPL MOPs detected memory fault Go to “MAP 1540: Minimum
Configuration” on page 52.
406C 00A0 IPL MOPs detected service
processor firmware fault
Update system firmware
160 Service Guide