Specifications
Table 7. Service Processor Error Codes (continued)
Error Code Description Action/ Possible Failing FRU
406B 0113 Wire tests detected memory DIMM
fault
Memory DIMM Location: P1-M2.14
406B 0114 Wire tests detected memory DIMM
fault
Memory DIMM Location: P1-M2.4
406B 011D Wire tests detected memory DIMM
fault
Memory DIMM Location: P1-M2.3 x4
406B 0121 Wire tests detected memory DIMM
fault
Memory DIMM Location: P1-M2.11
406B 0122 Wire tests detected memory DIMM
fault
Memory DIMM Location: P1-M2.5
406B 0123 Wire tests detected memory DIMM
fault
Memory DIMM Location: P1-M2.12
406B 0124 Wire tests detected memory DIMM
fault
Memory DIMM Location: P1-M2.6
406B 012D Wire tests detected memory DIMM
fault
Memory DIMM Location: P1-M2.5 x4
406B 0131 Wire tests detected memory DIMM
fault
Memory DIMM Location: P1-M2.9
406B 0132 Wire tests detected memory DIMM
fault
Memory DIMM Location: P1-M2.7
406B 0133 Wire tests detected memory DIMM
fault
Memory DIMM Location: P1-M2.10
406B 0134 Wire tests detected memory DIMM
fault
Memory DIMM Location: P1-M2.8
406B 013D Wire tests detected memory DIMM
fault
Memory DIMM Location: P1-M2.7 x4
406B 01FF Wire tests detected memory failure
on riser card 2 that cannot be
automatically isolated.
Go to “MAP 1540: Minimum
Configuration” on page 52, and run
minimum configuration for further
isolation.
406B 0200 Wire tests detected memory riser
card fault
Memory DIMM Location: P1-M1
406B 0201 Wire tests detected memory DIMM
fault
Memory DIMM Location: P1-M1.15
406B 0202 Wire tests detected memory DIMM
fault
Memory DIMM Location: P1-M1.1
406B 0203 Wire tests detected memory DIMM
fault
Memory DIMM Location: P1-M1.16
406B 0204 Wire tests detected memory DIMM
fault
Memory DIMM Location: P1-M1.2
406B 020D Wire tests detected memory DIMM
fault
Memory DIMM Location: P1-M1.1 x4
158 Service Guide