Specifications

Table 7. Service Processor Error Codes (continued)
Error Code Description Action/ Possible Failing FRU
406A 0332 Self tests detected memory DIMM
fault
Memory DIMM Location: P1-C1-M4
406A 033D Self tests detected memory DIMM
fault
Memory DIMM Location: P1-C1-M4
x2
406A 03FF Self tests detected memory failure on
processor card that cannot be
automatically isolated.
Go to “MAP 1540: Minimum
Configuration” on page 52, and run
minimum configuration for further
isolation.
406A 3101 Self tests detected RIO port 0 fault
1. RIO port 0, Location: P1-C1
2. System board, Location: P1
406A 3281 Self tests detected RIO port 0 fault 1. RIO port 0, Location: P1-C1
2. System board, Location: P1
406A 3284 Self tests detected PCI controller
PHB0 fault
Replace the system board. Location:
P1 (See note 3 on page 37.)
406A 3285 Self tests detected PCI controller
PHB1 fault
Replace the system board. Location:
P1 (See note 3 on page 37.)
406A 3286 Self tests detected PCI controller
PHB2 fault
Replace the system board. Location:
P1 (See note 3 on page 37.)
406B 0001 Wire tests detected system board
fault
Replace the system board. Location:
P1 (See note 3 on page 37.)
406B 0003 Wire tests detected processor fault All processors, Location: P1-C1
406B 0009 Wire tests detected memory fault Go to “MAP 1540: Minimum
Configuration” on page 52.
406B 00A0 Wire tests detected service processor
firmware fault
Update system firmware
406B 00A1 Wire tests detected system firmware
fault
1. Check for AIX updates
2. Check for system firmware
updates
406B 00A2 Wire tests detected service processor
firmware (PRD) fault
Update system firmware
406B 00A3 Wire tests detected memory plugging
fault
Go to “MAP 1540: Minimum
Configuration” on page 52.
406B 00A4 Wire tests detected application
caused fault
Application software
406B 00A5 Wire tests detected invalid system
configuration
Verify that system components are
supported and properly installed
156 Service Guide