Specifications
Table 7. Service Processor Error Codes (continued)
Error Code Description Action/ Possible Failing FRU
406A 0131 Self tests detected memory DIMM
fault
Memory DIMM Location: P1-M2.9
406A 0132 Self tests detected memory DIMM
fault
Memory DIMM Location: P1-M2.7
406A 0133 Self tests detected memory DIMM
fault
Memory DIMM Location: P1-M2.10
406A 0134 Self tests detected memory DIMM
fault
Memory DIMM Location: P1-M2.8
406A 013D Self tests detected memory DIMM
fault
Memory DIMM Location: P1-M2.7 x4
406A 01FF Self tests detected memory failure on
riser card 2 that cannot be
automatically isolated.
Go to “MAP 1540: Minimum
Configuration” on page 52, and run
minimum configuration for further
isolation.
406A 0200 Self tests detected memory riser card
fault
Memory DIMM Location: P1-M1
406A 0201 Self tests detected memory DIMM
fault
Memory DIMM Location: P1-M1.15
406A 0202 Self tests detected memory DIMM
fault
Memory DIMM Location: P1-M1.1
406A 0203 Self tests detected memory DIMM
fault
Memory DIMM Location: P1-M1.16
406A 0204 Self tests detected memory DIMM
fault
Memory DIMM Location: P1-M1.2
406A 020D Self tests detected memory DIMM
fault
Memory DIMM Location: P1-M1.1 x4
406A 020E Self tests detected memory pair A
fault
Memory Pair A, Location: P1-M1.1 x2
406A 0211 Self tests detected memory DIMM
fault
Memory DIMM Location: P1-M1.13
406A 0212 Self tests detected memory DIMM
fault
Memory DIMM Location: P1-M1.3
406A 0213 Self tests detected memory DIMM
fault
Memory DIMM Location: P1-M1.14
406A 0214 Self tests detected memory DIMM
fault
Memory DIMM Location: P1-M1.4
406A 021D Self tests detected memory DIMM
fault
Memory DIMM Location: P1-M1.3 x4
406A 0221 Self tests detected memory DIMM
fault
Memory DIMM Location: P1-M1.11
406A 0222 Self tests detected memory DIMM
fault
Memory DIMM Location: P1-M1.5
154 Service Guide