Specifications

Table 7. Service Processor Error Codes (continued)
Error Code Description Action/ Possible Failing FRU
4069 0009 Memory tests detected memory fault Go to “MAP 1540: Minimum
Configuration” on page 52.
4069 00A0 Memory tests detected service
processor firmware fault
Update system firmware
4069 00A1 Memory tests detected system
firmware fault
1. Check for AIX updates
2. Check for system firmware
updates
4069 00A2 Memory tests detected service
processor firmware (PRD) fault
Update system firmware
4069 00A3 Memory tests detected memory
plugging fault
Go to “MAP 1540: Minimum
Configuration” on page 52.
4069 00A4 Memory tests detected application
caused fault
Application software
4069 00A5 Memory tests detected invalid system
configuration
Verify that system components are
supported and properly installed
4069 00A6 Memory tests detected no usable
memory
1. Ensure that memory is properly
installed
2. If more than one DIMM is called
out, go to the service processor
Memory
Configuration/Deconfiguration
Menu to verify memory DIMMs
state. See Memory
Configuration/Deconfiguration
Menu on page 260 for more
information.
3. Go to “MAP 1540: Minimum
Configuration” on page 52
4. If the problem is not fixed, call
service support.
4069 00A7 Memory tests detected hardware
problem
Go to “MAP 1540: Minimum
Configuration” on page 52.
4069 00B0 Memory tests detected bus controller
lock-unlock failure
System board, Location: P1
4069 00B1 Memory tests diagnostics detected
bus controller failure
System board, Location: P1
4069 00B7 Memory test detected insufficient
hardware resources to continue IPL
This error code appears after the
initial testing by the service processor
firmware on the processors and
memory completed successfully, but
a problem occurred when the
firmware tried to communicate
outside the processor and memory
complex. Suspect a problem with the
backplane, location: P1.
4069 0100 Memory tests detected memory riser
card fault
Memory riser card Location: P1-M2
148 Service Guide